Pump Selection Guide

Discover the ideal pump for your needs from our extensive model list at BLDC PUMP. If you’re unsure about which pump to choose, our Select Guide is here to offer insightful tips and guidance. We’ve designed this page to streamline your selection process, ensuring you find the perfect pump effortlessly. Please note that all pump parameters can be customized to meet your specific requirements. Should you have unique needs, we encourage you to submit a request. Let us help you navigate our options to optimize your project’s efficiency and performance.

Circulation Pump Model List

ModelRated voltage (V DC)InletOutletMax flow rate (L/H)Max static head (M)Download
DC26A-12401212mm8mm5004

DC26B-12401214mm10mm5004

DC30A-1230128mm8mm2403

DC35-0512510mm10mm1701.2

DC35-1218122001.8
DC40-12501214mm10mm5205

DC40-2470246607
DC40A-12451214mm14mm6204.5

DC40A-2460248406
DC40C-1240121/2″ thread1/2″ thread7204

DC40C-2460249006
DC40D-12501210mm10mm4505

DC40D-2480245508
DC40F-1240121/2″ thread1/2″ thread7804

DC40F-2460249606
DC40H-12651211mm8mm3606.5

DC40H-241102445011
DC40M-12351212mm10mm5303.5

DC45A-12501212mm12mm6005

DC45A-1280127008
DC45A-181001875010
DC45A-241202485012
DC45B-12501210mm10mm6005

DC45B-1280127008
DC45B-181001875010
DC45B-241202485012
DC45C-1240121/2″ thread1/2″ thread7604

DC45C-12601210006
DC45C-18651811006.5
DC45C-24802412508
DC45D-12401214mm14mm9004

DC45D-12601212006
DC45D-18751812507.5
DC45D-24902413509
DC45E-1240121/2″ thread1/2″ thread9004

DC45E-12601212006
DC45E-18751812507.5
DC45E-24902413509
DC45I-1250121/2″ thread1/4″ thread6005

DC45I-1280127008
DC45I-181001875010
DC45I-241202485012
DC50A-12351227mm27mm30003.5

DC50A-24502436005
DC50B-121001220mm20mm156010

DC50B-2413024180013
DC50C-1260121/2″ thread1/2″ thread21006

DC50C-24802424008
DC50D-12601220mm20mm21006

DC50D-24802424008
DC50E-12110121/2″ thread1/2″ thread132011

DC50E-2415024156015
DC50F-12110121/2″ thread1/2″ thread132011

DC50F-2415024156015
DC50G-1260121/2″ thread1/2″ thread21006

DC50G-24802424008
DC50H-121501214mm7mm50015

DC50H-242002460020
DC50K-121201214mm14mm126012

DC50K-2416024138016
DC50M-1290121/2″ thread1/2″ thread12009

DC50M-24802411508
DC50M-2413024135013
DC55A-121201220mm20mm170012

DC55A-1816018180016
DC55A-2416024180016
DC55A-3616036180016
DC55B-121201220mm20mm200012

DC55B-1816018240016
DC55B-2416024240016
DC55B-3616036240016
DC55E-12120121/2″ thread1/2″ thread200012

DC55E-1816018240016
DC55E-2416024240016
DC55E-3616036240016
DC55F-12120121/2″ thread1/2″ thread170012

DC55F-1816018180016
DC55F-2416024180016
DC55F-3616036180016
DC55I-121501212mm10mm70015

DC55I-182001880020
DC55I-242002480020
DC55I-362003680020
DC55K-121701210mm10mm47017

DC55K-242502455025
DC55JB-122401220mm20mm180024

DC55JB-1832018200032
DC55JB-2432024200032
DC55JB-3632036200032
DC55JE-12240121/2″ thread1/2″ thread180024

DC55JE-1832018200032
DC55JE-2432024200032
DC55JE-3632036200032
DC56B-121001220mm20mm210010

DC56B-1814018270014
DC56B-2414024270014
DC56B-3614036270014
DC56E-12100121/2″ thread1/2″ thread210010

DC56E-1814018270014
DC56E-2414024270014
DC56E-3614036270014
DC60B-121001225mm25mm320010

DC60B-1812018380012
DC60B-2412024380012
DC60B-3612036380012
DC60D-121001220mm20mm320010

DC60D-1812018380012
DC60D-2412024380012
DC60D-3612036380012
DC60E-12100121/2″ thread1/2″ thread320010

DC60E-1812018380012
DC60E-2412024380012
DC60E-3612036380012
DC60G-12100123/4″ thread3/4″ thread320010

DC60G-1812018380012
DC60G-2412024380012
DC60G-3612036380012
DC80D-12601238mm38mm66006

DC80D-18901875009
DC80D-2410024800010
DC80D-3610036800010
DC80D-4810048800010
DC80E-1260121″ thread1″ thread66006

DC80E-18901875009
DC80E-2410024800010
DC80E-3610036800010
DC80E-4810048800010
DC85D-12501238mm38mm100005

DC85D-188018120008
DC85D-24100241350010
DC85D-36100361350010
DC85D-48100481350010
DC85E-1250121-1/4″ thread1-1/4″ thread100005

DC85E-188018120008
DC85E-24100241350010
DC85E-36100361350010
DC85E-48100481350010

Selection Guide

Choosing the right pump for your application is crucial for achieving optimal performance and efficiency. This guide simplifies the process, ensuring you select the perfect pump to meet your specific needs.

1. Understand Your Requirements

Flow Rate & Head: Determine the desired flow rate (LPH or GPH) and head height (meters or feet) your application requires. These are critical for ensuring the pump meets your system’s demands.

Operation Environment: Consider the liquid type (water, oil, acid/alkali solutions), temperature range, and whether the pump will be exposed to harsh chemicals.

Electrical Requirements: Identify the voltage and wattage your system can supply to ensure compatibility with the pump’s electrical requirements.

Continuous Operation: Assess if the pump needs to operate continuously and ensure it is designed for long-term use without overheating.

2. Choose the Right Model

Review our product catalog to identify pumps that match your flow rate, head height, and operational environment needs. Remember, BLDC pumps are known for their efficiency, compact design, and reliability in various applications, from automotive cooling systems to aquarium setups.

3. Consider Customization Options

Wire Length & Plug Type: Customize the power wire length and plug type to suit your installation requirements.

Pump Appearance: Utilize our mold factory for quick development of custom dimensions and inlet/outlet orientations.

Material Adaptation: Select materials compatible with your specific liquid type, ensuring longevity and reliability.

Labeling & Packaging: Enhance your brand with custom labels and packaging options.

Voltage & Wattage: Specify the operational voltage and wattage for seamless integration into your system.

Control Program Development: Collaborate with our engineers to develop a unique control program, enhancing functionality and integration with your system.

4. Additional Features and Protection

  • Evaluate pumps with built-in protection features such as dry run, overload, and thermal protection for increased durability and safety.
  • Consider pumps with adjustable flow rates and the ability to operate in submersible or external configurations, depending on your application.

5. Consult with Experts

If uncertain, reach out to our skilled technicians for advice. We can guide you through selecting the perfect pump, considering your unique requirements and offering solutions tailored to your application.

Making Your Choice

Selecting the right water pump is more than just matching specifications. It’s about understanding your system’s unique demands and finding a pump that can meet those needs efficiently and reliably. With BLDC PUMP’s expertise and wide range of customizable options, you’re sure to find a solution that not only fits but enhances your application.

Tell us your requests to get solution. Let's push things forward.

Submit a Quick Quote

    bldc pump product catalog cover 2024 400x500

    Grab Free Product Catalog

    Before you go, grab your free BLDC Pump Product Catalog! Quick sign-up below to find innovative pump solutions that might be just what you need in the future.